Features:

1. Suitable for energy-saving and consumption reduction of various types of vertical elevators.
2. Installation is simple and convenient, with only 2 wires connected to the positive and negative poles on the DC side of the frequency converter. Energy storage type energy recovery, the comprehensive power saving efficiency is up to 35%.
3. The DC side is recycled and has no impact on the power grid.



Topology diagram:




Specification parameter table:

Technical Parameter

high voltage terminal

Voltage range(Vdc)

450~750

Current range(A)

0~30

rated power(KW)

10

Low voltage end

Voltage range(Vdc)

90~135

Current range(A)

0~80

conversion efficiency

Greater than 95% (obtained under experimental conditions)

Low voltage end

Automatic energy recovery, adaptive charging and discharging power

Interface

RS485

Modbus RTU (isolated), 1 channel

CAN

CAN2.0A/B (isolated), 1 circuit

Protection and alarm

High voltage side overvoltage/undervoltage/reverse connection protection; Low voltage side overvoltage/undervoltage protection; Low voltage side overcurrent/short circuit protection; Over temperature protection, automatic recovery after the protection point disappears

General

protection grade

IP20

Cooling method

风冷

Installation method

Cabinet with pulley, movable (see specifications for details)

operation temperature(℃)

-10 ℃~+40 ℃, derated for use above 40 ℃

work environment

Humidity<90% RH, non condensing; Altitude<4000m, derating required if exceeding 3000m

Use; The surrounding environment is free of corrosive gases, conductive dust, and flammable and explosive media

Existence; No severe vibration, turbulence, rain or snow erosion, and installation inclination not exceeding 5 degrees

noise

Under rated operating conditions, the operating noise of the module at a distance of 1M is less than 45dB

Overall dimensions and weight

size(D*W*H) mm

320*440*970

weight(Kg)

≤85

Industry application
The basic principle of photovoltaic power generation is "photovoltaic effect"". Photon irradiation to metal, its energy can be one electron of the metal absorption, electronic absorption energy is large enough,
can overcome the gravity acting within the metal, leaving the metal surface to escape, a photoelectron.

Cooperation

Wenlida Always to "high standards, fine production, strict control, perfect" as the concept, products and services to create a stable leader brand!
021-31587108
Message
  Message         Complaint         Inquiry          Other
*
*
*
Please leave your real email or telephone so that our staff can reply and answer them in time!
*
*