20T行车节能系统应用案例 | 20T Crane Energy-Saving System Case
|
出品方:稳利达电力电子 | Wenlida Power Electronics |
项目简介 | Project Introduction
本项目为20吨桥式起重机(行车)势能回收节能系统,由稳利达电力电子提供整套超级电容储能与DCDC变换解决方案。设备由1台17.15kW双向DCDC模块与5串48V187.5F超级电容模组构成,接入行车变频器直流母线,实现主钩下降势能的高效回收与释放。行车下放重物时,势能通过DCDC转换为电能储存于超级电容(120-240Vdc);提升或重载作业时,超容能量经DCDC回馈至直流母线,辅助电机做功,显著降低行车电能消耗与电网冲击。系统配置10寸触摸屏、RS485(Modbus RTU)与以太网(Modbus TCP)双通道通讯,具备完备的过压、欠压、过流、过温及通讯保护,故障解除后自动恢复运行,自然冷却、IP20防护,适用于各类工业厂房桥式起重机、门式起重机、冶金铸造起重机的节能改造。
This project is a potential-energy-recovery energy-saving system for a 20-ton bridge crane (overhead travelling crane), delivered by Wenlida Power Electronics as a complete super-capacitor storage and DC-DC conversion solution. The unit consists of one 17.15kW bidirectional DC-DC module and five 48V187.5F super-capacitor modules in series, connected to the crane inverter DC bus to efficiently recover and release the potential energy of the main hook. When the crane lowers a load, potential energy is converted via the DC-DC module into electricity stored in the super-capacitors (120-240Vdc); during lifting or heavy-load operation, the stored energy is fed back to the DC bus to assist the motor, significantly reducing energy consumption and grid impact. The system features a 10-inch touch screen, dual-channel RS485 (Modbus RTU) and Ethernet (Modbus TCP) communication, comprehensive over-/under-voltage, over-current, over-temperature and communication protections, and auto-recovery after fault clearance. It is naturally cooled with IP20 protection, and is suitable for energy-saving retrofit of bridge cranes, gantry cranes and metallurgical casting cranes in industrial plants.
系统拓扑说明 | System Topology Description

|
图1:系统拓扑图 | Figure 1: System Topology Diagram |
|
图2:行车节能系统应用场景(见下方配图)| Figure 2: Crane energy-saving system application scenario (see image below) |
图2:20T行车节能系统应用场景 | Figure 2: 20T crane energy-saving system application scenario
整套系统配置10寸本地触摸屏,供客户监控数据和触摸操作;提供一路RS485接口,支持遥控、遥测、遥调功能。超级电容组经DCDC低压侧接入(120-240Vdc),DCDC高压侧接入行车变频器直流母线(450-750Vdc)。行车下降时超容充电储能,提升时超容放电回馈母线,形成"势能—电能—机械能"的闭环能量利用。
The system is equipped with a 10-inch local touch screen for on-site data monitoring and touch operation, and one RS485 port for remote telecontrol, telemetry and tele-adjustment. The super-capacitor bank connects to the low-voltage side of the DC-DC module (120-240Vdc), while the high-voltage side connects to the crane inverter DC bus (450-750Vdc). During lowering, the super-capacitors charge and store energy; during lifting, they discharge back to the bus, forming a closed-loop "potential energy – electrical energy – mechanical energy" utilization.
势能回收计算 | Potential-Energy Recovery Calculation
|
计算项目 Item |
结果 Result |
|
工况条件 Working Condition |
载重 20t;常用提升高度 h=5m;下降速度 7.5m/min = 0.125m/s |
|
重力势能 Potential Energy |
E = m·g·h = 20t × 9.8 × 5m = 980kJ |
|
按 70% 效率回收 Recovered Energy (η=0.7) |
E? = 0.7 × 980kJ = 686kJ |
|
回收功率 Recovery Power |
P = m·g·v = 20t × 9.8 × 0.125 = 24.5kW |
|
按 70% 效率回收 Recovered Power (η=0.7) |
P? = 0.7 × 24.5kW = 17.15kW |
|
超容配置 Capacitor Config. |
48V/187.5F 标准模组 × 5串;等效容量 187.5/5 = 37.5F |
|
超容电压区间 Voltage Range |
120-240V(5×48V,留有裕量) |
|
超容可用能量 Usable Energy |
E = ?·C·U? = 0.5 × 37.5 × (240? ? 120?) = 810kJ > 686kJ ? |
|
超容**大电流 Max. Capacitor Current |
I = 17.15kW / 120V ≈ 143A(满足正常使用)? |
|
结论:超容储能 810kJ 大于需回收能量 686kJ,超容**大电流约 143A 满足使用要求,配置合理。The 810kJ super-capacitor capacity exceeds the 686kJ recovery demand, and the ~143A max current is within the usable range — configuration verified. |
完整全套参数表 | Complete Parameter Tables
表1 17.15kW DCDC模块电气参数 | Table 1 Electrical Parameters of 17.15kW DC-DC Module
|
序号 No. |
电气类目 Category |
详细类目 Item |
规格 Specification |
|
1 |
直流电压 DC Voltage |
超容侧 / 母线侧 Cap-side / Bus-side |
120-240Vdc / 450-750Vdc |
|
2 |
直流电流 DC Current |
超容侧 / 母线侧 Cap-side / Bus-side |
≤200A / ≤39A |
|
3 |
转换效率 Efficiency |
HV 700V / LV 600V |
98% (lab conditions) |
|
4 |
额定功率 Rated Power |
|
17.15kW |
|
5 |
工作模式 Operation Mode |
|
CV / CC (configurable) |
|
6 |
电压稳定度 Voltage Stability |
静态 / 动态 |
±1% / ±3% |
|
7 |
电流稳定度 Current Stability |
静态 / 动态 |
±1% / ±3% |
|
8 |
通信接口 Communication |
|
RS485 isolated (Modbus RTU); CAN2.0A/B isolated (up to 1M/s) |
|
9 |
供电方式 Power Supply |
|
220Vac or DC customization |
|
10 |
保护 Protection |
|
HV/LV over-/under-voltage, over-current, over-temperature, communication; auto-recovery |
|
11 |
尺寸 / 重量 Dimension / Weight |
L×W×H |
500 × 363 × 154 mm / 37kg |
|
12 |
散热方式 Cooling |
|
Air cooling |
表2 整机规格参数 | Table 2 Complete Unit Specifications
端口 Port
项目 Item
参数 Parameter
变频器直流母线接口
电压范围 Voltage (Vdc)
450-750
**大电流 Max. Current (A)
39
额定功率 Rated Power (kW)
17.15
整机基本参数
工作温度范围 Operating Temp. (℃)
-10 ~ +45
相对湿度 Relative Humidity
0 ~ 90%, non-condensing
**工作海拔 Max. Altitude (m)
2000
冷却方式 Cooling
Natural cooling
显示 Display
Touch screen
系统供电 Aux. Power
AC220V (User-supplied)
通讯方式 Communication
RS485 (Modbus RTU) / Ethernet (Modbus TCP)
防护等级 Protection Class
IP20
重量 Weight (kg)
≈600
尺寸 (宽×深×高 mm)
800 × 800 × 1800 (Tentative)
Inverter DC-bus Port
General Unit Parameters
设备搬运说明 | Equipment Handling Instruction
机柜底座开有两个方形孔,搬运时叉车两根货叉通过方形孔叉入机柜底部,移动过程中需保证缓慢、平稳,避免设备磕碰倾倒。
Two square holes are reserved at the cabinet base. Insert two forklift forks through the square holes to the cabinet bottom during handling. Move slowly and steadily to prevent collision or tipping-over.
应用场景 | Application Scenarios
典型应用 | Typical Applications
? 工业厂房20T及以下桥式起重机(行车)势能回收
? 冶金铸造起重机、门式起重机节能改造
? 港口门座起重机、料场抓斗起重机下放势能回收
? 电梯、提升机、立体车库重力势能回收
? 冲击性负载电网缓冲与功率平抑
? Potential-energy recovery for industrial-plant bridge cranes up to 20T
? Energy-saving retrofit of metallurgical casting cranes and gantry cranes
? Lowering-energy recovery for port portal cranes and grab cranes
? Gravitational-potential recovery for elevators, hoists and automated parking systems
? Grid buffering and power smoothing for surge loads
|
定制说明:稳利达电力电子本系列产品支持定制开发,可根据行车载重、提升高度、下降速度、超容容量与DCDC功率灵活配置,适配不同项目的节能改造需求。 Customization Note: Customization available by Wenlida Power Electronics. Crane lifting capacity, lifting height, lowering speed, super-capacitor capacity and DC-DC power rating can be flexibly configured according to site conditions to meet various retrofit requirements. |